ERP vs EIRP
Edit on GitHubThe difference between ERP and EIRP, how antenna gain changes the legal number, and which one your regulator means.
ERP vs EIRP
Regulators quote power limits in either ERP or EIRP. Mixing them up can make you think you are legal when you are not.
The definitions
- ERP (effective radiated power): the power a half-wave dipole would need to produce the same field. It ignores the gain of a simple antenna beyond dipole equivalence.
- EIRP (effective isotropic radiated power): the power an isotropic (perfectly spherical) radiator would need. It includes the antenna gain over isotropic.
The difference is 2.15 dB: EIRP = ERP + 2.15 dB (for a dipole compared to isotropic).
Which limits use which
- EU 433 MHz ISM: often quoted as 10 mW ERP.
- PMR446: 500 mW ERP.
- Amateur: usually no ERP limit; power is quoted at the transmitter output.
- FCC: often uses EIRP.
The antenna gain trap
If the limit is 10 mW ERP and your antenna has 3 dBi of gain, the transmitter output must be reduced so that ERP stays under the limit. A high-gain antenna does not make you more legal; it reduces the allowed transmitter power.
For the beacon:
- The default whip antenna has roughly 0 dBi gain (unity).
- A ground-plane setup adds ~3 dBi, which counts against ERP/EIRP limits.
Working the numbers
At +17 dBm (50 mW) with a unity antenna:
- ERP = 50 mW × (0.75 for the mismatch losses) ≈ 37 mW ≈ +15.7 dBm ERP - still above the 10 mW ISM limit.
- To meet 10 mW ERP you would need to transmit at about +7 dBm with losses.
The practical takeaway
If your regulator says “10 mW ERP”, the beacon’s +17 dBm default is not compliant without a license. Use the dashboard’s power slider to test below the limit, or operate under a license. The legal pages and the regional frequency table give the numbers per country.